Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsS type load cell

S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer

Good quality Reaction torque sensor for sales
Good quality Reaction torque sensor for sales
I'm Online Chat Now

S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer

China S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier
S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer supplier

Large Image :  S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer

Product Details:

Place of Origin: China
Brand Name: Forsentek
Certification: CE
Model Number: FSRG

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Packaging Details: Shockproof carton
Delivery Time: 3-20 working days
Payment Terms: T/T, Western Union, MoneyGram,Paypal
Supply Ability: 3710pcs/month
Contact Now
Detailed Product Description
Material: Stainless Capacity: 0-20klb(Selectable)
Output: Analog Type: Tension/Compression
Ingress Protection: IP67

S-Type Load Cell 20klb 15klb 10klb 5klb 3klb 2klb 1klb 500 lbf S Beam Force Transducer

High Accuracy S-beam Load Cell FSRG is made based on strain gauge technology with unified 3.0mV/V output intended for both tension and compression force measurement, S-beam Force Transducer FSRG offers 0-50lb / 0-100lb / 0-150lb / 0-200lb / 0-250lb / 0-300lb / 0-500lb / 0-1klb / 0-1.5klb / 0-2klb / 0-2.5klb / 0-3klb / 0-5klb / 0-10klb / 0-15klb / 0-20klb sixteen rated measuring ranges to choose from. High accuracy with maximum 0.02% non-linearity of the full scale. Universal s-beam load cell FSRG is hermetically sealed to IP67 with both metric and imperial threads available. S Type Force Sensor FSRG is applicable for rope and chain strength testing,bagging machines,material testing machines, hanging scales, hoppers weighing applications.You may find transducer FSRG interchangeable with Siemens SIWAREX WL250 ST-S SA,VPG Revere 9363, Artech model SS 20210, Rice Lake RL20000ST, ptglobal PT4000, Rice Lake RL20000SS, VPG Sensortronics 60050 with lower cost but uncompromised quality.

s beam force sensor 50 lb 100lb 200 lbf 300lb 500 lbs type force transducer 500 lb 300lb 250 lbf 200lb 150lb
Specifications

Rated capacity

50lb / 100 lb / 150lb / 200lb / 250 lb / 300lb / 500lb /

1klb / 1.5klb / 2k lb / 2.5klb / 3klb / 5klb / 10klb / 15klb / 20klb

Rated output 3.0 mV/V Compensated temperature -10...+40oC
Excitation 3-15V Operating temperature -35...+65oC
Zero balance ±0.03mV/V Temperature shift zero ±0.02% R.O./10oC
Nonlinearity ±0.02% R.O. Temperature shift span ±0.02% R.O./10oC
Hysteresis ±0.02% R.O. Input resistance 430±60 ohms
Nonrepeatability ±0.01% R.O. Output resistance 352±3 ohms
Creep(30min) ±0.02% R.O. Insulation resistance >5000Mohms
Safe overload 150% F.S. Ingress protection IP67
Ultimate overload 250% F.S. Material of element Stainless steel
Cable Ø5*6000mm 4-core shielded
Wiring code

Compression@
Red--Power input+     Black--Power input-
Green--Signal output+     White--Signal output-

 

Load cell glossary:

Load Cell:A device which produces an output signal proportional to the applied weight or force.

Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.
Excitation: The voltage applied to the input terminals of the load cell.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.