Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMicro load cell

Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N

Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N

    • Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N
    • Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N
    • Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N
    • Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N
  • Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FMZJ

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 48760pcs/month
    Contact Now
    Detailed Product Description
    Type: Smallest Weight Sensor Output: Analog
    Usage: Weight Measurement Length: 20mm
    Range: 0-1kg Material: Aluminum
    Structure: Single Ended Beam Type

    Smallest Beam Load Cell Sensor 1kg Smallest Weight Transducer 10N

    Smallest Weight Sensor FMZJ is strain gauge based intended for weight measurement within range of 0-1kg. Smallest Load Cell FMZJ utilizes 1000 ohms high resistance strain gauges,which is more energy-efficient and has better stability in the long run compared to commonly used 350 ohms strain gages. Aluminum construction, lightweight design with only 1g self-weight, miniature load sensor FMZJ is suitable for portable weighing devices. You may find subminiature weight transducer FMZJ applicable for weight monitoring & controlling in smart coffee machine, force simulators,home appliances, portable force measuring devices, game consoles,and so on. If you are looking for similar weighing sensors with different measuring ranges,custom made service is also available at Forsentek.

    smallest load cell 1kgsmallest weight transducer 1kg

    Specifications

    Rated capacity

    1kg / 10N / 2.2lb

    Customizable

    Sensitivity 1.0 mV/V Compensated temperature 0...+40oC
    Excitation 3-10V Operating temperature -10...+60oC
    Zero balance ±0.1mV/V Temperature shift zero ±0.05% R.O./oC
    Nonlinearity ±0.1% R.O. Temperature shift span ±0.05% R.O./oC
    Hysteresis ±0.1% R.O. Input resistance 1000±100 ohms
    Nonrepeatability ±0.05% R.O. Output resistance 1000±100 ohms
    Creep(2min) ±0.05% R.O. Insulation resistance >2000Mohms
    Safe overload 120% F.S. Ingress protection IP60
    Ultimate overload 200% F.S. Material of element Aluminum
    Cable AWG32*80mm(Longer cable upon request)
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-

     

    Load cell glossary:

    Load Cell:A device which produces an output signal proportional to the applied weight or force.

    Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.
    Excitation: The voltage applied to the input terminals of the load cell.

    Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

    Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

    Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

    Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

    Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

    Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

    Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

    Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

    Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

    Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.