    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FL25

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 3360pcs/month
    Contact Now
    Detailed Product Description
    Material: Stainless Capacity: 0-220lbf(Selectable)
    Output: Analog Thread: M5/M6
    Direction: Compression/Tension

    M5/M6 Threaded Pull Load Cell 10 lb 20lb 50 lb 100lb 200 lb Tension Force Transducer

    Threaded in-line Compression And Tension Load Cell FL25 is made of 17-4 stainless steel and CE certified. Rod End Force Transducer FL25 offers rugged structure with 0-11lb / 0-22lb / 0-44lb / 0-66lb / 0-110lb / 0-132lb / 0-220lb seven measuring ranges to choose from.Inline load cells are designed to be mounted inline to the load axis for both tension and compression force measurement.In-line Force Transducer FL25 can be easily mounted to existing system through M5 or M6 threaded rods located on both sides of the transducer,these metric threads can also be used to mount attachments,such as female eye bolt,bolt adapter,etc.,to fit different usage requirements. Push And Pull Force Sensor FL25 uses metal foil strain gauge technology to deliver 2.0mV/V rated output with 0-5kg / 0-10kg / 0-20kg / 0-30kg / 0-50kg / 0-60kg / 0-100kg seven rated measuring ranges to choose from. Each sensor is integrated with a 4-meter-long 4-core shielded cable,the cable comes with a free end which makes it easy to assemble any types of connectors for electrical connection. Inline Type Tension Compression Load Cell FL25 is normally used for press-in force measurement, cylinder push pull force measurement, auto equipment, production line, hand press machine.etc.Model FL25 can be modified or customized as per request of our clients.

    inline tension load cell 10lb 20 lb 50lb 100 lb 200lbinline pull load cell 10lb 20 lb 50lb 100 lb 200lb

    Specifications

    Rated capacity

    50N / 5kg / 11 lbf

    100N / 10kg / 22 lbf

    200N / 20kg / 44 lbf

    300N / 30kg / 66 lbf

    500N / 50kg / 110 lbf

    600N / 60kg / 132 lbf

    1000N / 100kg / 220 lbf

    Rated output 2.0 mV/V Compensated temperature -10...+40oC
    Excitation 3-15V Operating temperature -20...+60oC
    Zero balance ±0.05mV/V Temperature shift zero ±0.02% R.O./oC
    Nonlinearity ±0.5% R.O. Temperature shift span ±0.02% R.O./oC
    Hysteresis ±0.5% R.O. Input resistance 750±100 ohms
    Nonrepeatability ±0.2% R.O. Output resistance 750±100 ohms
    Creep(10min) ±0.1% R.O. Insulation resistance >5000Mohms
    Safe overload 150% F.S. Ingress protection IP64
    Ultimate overload 200% F.S. Material of element Stainless steel
    Cable Ø3*4000mm 4-core shielded cable
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-


    A load cell (or loadcell) is a transducer which converts force into a measurable electrical output. Although there are many varieties of loadcells, strain gauge load cells are the most commonly used type which is comprised of a solid metal body on which strain gauges have been secured to form a wheatstone bridge which delivers mV/V output.

    Load cell output: = (Power supply * Rated output) * Load / Capacity

    Rated output of push pull load cell FL25 is around 2mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the output range of compression tension sensor FL25 is normally within -30mV...+30mV.
    Example: Cylindrical Push Pull Force Sensor FL25-50kg with 2.0mV/V sensitivity powered by 5V DC,the output range is -10mV...+10mV.
    Load cell + Signal amplifier:A signal conditioner can be used to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.

    Example: Compression And Tension Load Cell FL25-10kg working with amplifier FSC(-10-10V)-24V,the load-voltage relationship will be 0-10kg compression load VS 0-10V output, 0-10kg tension load VS 0-(-10V) output.