Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsOther products

M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor

M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor

    • M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor
    • M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor
    • M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor
    • M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor
  • M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FCMA

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 3360pcs/month
    Contact Now
    Detailed Product Description
    Type: Pancake Load Cell Capacity: 0-1000kg(Seletable)
    Output: Analog Load Direction: Tension Compression
    Thread: M16

    M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor

    Universal pancake load cell FCMA is made of high stiffness alloy steel based on foil strain gauge technology to deliver 2.0mV/V rated output proportional to the applied force.Pancake load cell FCMA offers 30kg / 50kg / 100kg / 200kg / 300kg / 500kg / 1000kg seven different measuring ranges with maximum 0.1% non-linearity of the rated output to choose from intended for both static and dynamic force measurement,low profile load cell FCMA can be used for both tension and compression measurement,low profile structure makes it also suitable for in-line force monitoring.Model FCMA is designed with a M16x1.5 threaded hole running through the center of the transducer which can be used to mount attachments such as load buttons,eye bolts or other adapters for force loading,this makes spoke type load cells very adaptable to various cases,you may find pancake type load cell FCMA applicable for force measurement in injection-molding machines,press machines and material testing equipment,weight measurement for tanks,vessels and hoppers, and so on.

    universal_pancake_load_cell

    Dimensions

    M16 threaded pancake load cell 10kN 5kN 3kN 2kN 1kN 500N 300N compression sensor

    Specifications

    Capacity

    30kg / 300N / 66lbf

    50kg / 500N / 110 lbf

    100kg / 1kN / 220 lb

    200kg / 2kN / 440lb

    300kg / 3kN / 660lbf

    500kg / 5kN / 1.1 klb

    1000kg / 10kN / 2.2klbf

    Rated output 2.0mV/V
    Excitation 3-15V
    Zero balance ±0.05mV/V
    Nonlinearity ±0.1% R.O.
    Hysteresis ±0.1% R.O.
    Nonrepeatability ±0.05% R.O.
    Creep(30min) ±0.05% R.O.
    Safe overload 150% F.S.
    Ultimate overload 200% F.S.
    Compensated temperature -10...+40oC
    Operating temperature -20...+60oC
    Temperature shift zero ±0.05% R.O./10oC
    Temperature shift span ±0.05% R.O./10oC
    Input resistance 750±50 ohms
    Output resistance 700±10 ohms
    Insulation resistance >5000M ohms
    Ingress protection IP65
    Material of element Alloy steel
    Cable Ø5*2000mm 4-core shielded
    Wiring code

    Red--Excitation+

    Black--Excitation-

    Green--Signal+

    White--Signal-

     

    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: 2.0mV/V load cell with 10V power supply,the output range is 0~20mV (-20mV...+20mV for bidirectional sensor).
    Example two: 1.0mV/V load cell with 5V power supply,the output range is 0~5mV (-5mV...+5mV for bidirectional sensor).

    Load cell + Signal amplifier:
    Load cell normally outputs -30mV...+30mV which sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
    Example: Compression load cell FCMA-500kg working with 0-10V amplifier FSC(0-10V)-24V, the load-output relationship will be 0-500kg load VS 0-10V output,which is linear within the error range.

    Load cell + Digital indicator
    Digital indicator can work directly with load cell without signal amplifier,here are some functions from the indicator:
    -Display force value in real time
    -Peak holding to grab the maximum force during testing
    -RS485 or RS232 interface
    -0-5V/0-10V/4-20mA analog output
    -Switch output

    compression_force_measurement_device

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)

    Other Products