    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FL25

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 3360pcs/month
    Contact Now
    Detailed Product Description
    Material: Stainless Steel Capacity: 5kg 10kg 20kg 50kg 100kg
    Output: Analog Output Principle: Strain Gauge Load Cell
    Connection: M5/M6 Thread Direction: Tension/Compression

    Rod End Tension Compression Force Sensor 1kN 500N 200N 100N 50N Cylindrical Load Cell

    Threaded Rod End Tension Compression Cylindrical Load Cell FL25 is made of 17-4 stainless steel and CE certified. Rod End Force Transducer FL25 offers rugged structure for industrial applications.Inline load cells are designed to be mounted inline to the load axis for both tension and compression force measurement.In-line Force Sensor FL25 can be easily mounted to existing system through M5 or M6 threaded rods located on both sides of the transducer,these metric threads can also be used to mount attachments,such as female eye bolt,bolt adapter,etc.,to fit different usage requirements. Tension and Compression Force Transducer FL25 uses metal foil strain gauge technology to deliver 2.0mV/V rated output with 0-50N / 0-100N / 0-200N / 0-300N / 0-500N / 0-600N / 0-1000N seven rated measuring ranges to choose from. Each sensor is integrated with a 4-meter-long 4-core shielded cable,the cable comes with a free end which makes it easy to assemble any types of connectors for electrical connection. Inline Type Tension Compression Load Cell FL25 is normally used for press-in force measurement, cylinder push pull force measurement, auto equipment, production line, hand press machine.etc.Model FL25 can be modified or customized as per request of our clients.

    Cylindrical Load Cell 100kg 50kg 20kg 10kg 5kgCylindrical Force Transducer 1kN 500N 200N 100N 50N

    Specifications

    Rated capacity

    50N / 5kg / 11lb

    100N / 10kg / 22lb

    200N / 20kg / 44lb

    300N / 30kg / 66lb

    500N / 50kg / 110lb

    600N / 60kg / 132lb

    1kN / 100kg / 220lb

    Rated output 2.0 mV/V Compensated temperature -10...+40oC
    Excitation 3-15V Operating temperature -20...+60oC
    Zero balance ±0.05mV/V Temperature shift zero ±0.02% R.O./oC
    Nonlinearity ±0.5% R.O. Temperature shift span ±0.02% R.O./oC
    Hysteresis ±0.5% R.O. Input resistance 750±100 ohms
    Nonrepeatability ±0.2% R.O. Output resistance 750±100 ohms
    Creep(10min) ±0.1% R.O. Insulation resistance >5000Mohms
    Safe overload 150% F.S. Ingress protection IP64
    Ultimate overload 200% F.S. Material of element Stainless steel
    Cable Ø3*4000mm 4-core shielded cable
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-


    A load cell (or loadcell) is a transducer which converts force into a measurable electrical output. Although there are many varieties of loadcells, strain gauge load cells are the most commonly used type which is comprised of a solid metal body on which strain gauges have been secured to form a wheatstone bridge which delivers mV/V output.

    Load cell output: = (Power supply * Rated output) * Load / Capacity

    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: Cylindrical Load Cell FL25-5kg with 2.0mV/V sensitivity powered by 3.3V DC,the output range is -6.6mV...+6.6mV.
    Example two: Inline Load Cell FL25-10kg with 2.0mV/V rated output powered by 5V DC,the output range is -10mV...+10mV.

    Load cell + Signal amplifier:
    A signal conditioner can be used to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
    Example: Tension And Compression Load Cell FL25-50kg working with amplifier FSC(-10-10V)-24V,the load-voltage relationship will be 0-50kg compression load VS 0-10V output, 0-50kg tension load VS 0-(-10V) output.

    Rod End Tension Compression Cylindrical Load Cell 100kg 50kg 20kg 10kg 5kg

    Miniature Cylindrical Load Cell

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)

    Other Products