Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsOther products

Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer

Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer

    • Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer
    • Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer
    • Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer
    • Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer
  • Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Model Number: FCMA

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 5000pcs/month
    Contact Now
    Detailed Product Description
    Material: Alloy Steel Capacity: 30kg 50kg 100kg 200kg 300kg 500kg 1000kg
    Output: Analog Output Principle: Strain Gauge Load Cell

    Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer

    Low profile compression load meter FCMA is made of high stiffness alloy steel based on foil strain gauge technology to deliver 2.0mV/V rated output proportional to the applied force.Pancake load cell FCMA offers 30kg / 50kg / 100kg / 200kg / 300kg / 500kg / 1000kg seven different measuring ranges with maximum 0.1% non-linearity of the rated output to choose from intended for both static and dynamic force measurement,low profile load cell FCMA can be used for both tension and compression measurement,low profile structure makes it also suitable for in-line force monitoring.Model FCMA is designed with a M16x1.5 threaded hole running through the center of the transducer which can be used to mount attachments such as load buttons,eye bolts or other adapters for force loading,this makes spoke type load cells very adaptable to various cases,you may find pancake type load cell FCMA applicable for force measurement in injection-molding machines,press machines and material testing equipment,weight measurement for tanks,vessels and hoppers, and so on.

    compression_load_sensor_1000kg_500kg_200kg_100kg_50kg

    Dimensions

    Compression load meter 1000kg 500kg 200kg 100kg 50kg force measurement transducer
    Specifications

    Capacity

    30kg / 300N / 66 lbf

    50kg / 500N / 110lbf

    100kg / 1kN / 220lb

    200kg / 2kN / 440 lb

    300kg / 3kN / 660 lbf

    500kg / 5kN / 1.1klb

    1000kg / 10kN / 2.2k lbf

    Rated output 2.0mV/V
    Excitation 3-15V
    Zero balance ±2% R.O.
    Nonlinearity ±0.1% R.O.
    Hysteresis ±0.1% R.O.
    Nonrepeatability ±0.05% R.O.
    Creep(30min) ±0.05% R.O.
    Safe overload 150% F.S.
    Ultimate overload 200% F.S.
    Compensated temperature -10...+40oC
    Operating temperature -20...+60oC
    Temperature shift zero ±0.05% R.O./10oC
    Temperature shift span ±0.05% R.O./10oC
    Input resistance 750±50 ohms
    Output resistance 700±10 ohms
    Insulation resistance >5000M ohms
    Ingress protection IP65
    Material of element Alloy steel
    Cable Ø5*2000mm 4-core shielded
    Wiring code Red--E+ Black--E- Green--S+ White--S-

     
     

    Load cell zero output:The output signal of the loadcell with no-load applied,expressed in mV/V or as a percentage of rated output.The zero output is caused by the stress during strain gauge bonding,it can be handled during calibration or signal processing without affecting the measurement accuracy.

    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: 2.0mV/V load cell with 10V power supply,the output range is 0~20mV (-20mV...+20mV for bidirectional sensor).
    Example two: 1.0mV/V load cell with 5V power supply,the output range is 0~5mV (-5mV...+5mV for bidirectional sensor).

    Load cell + Signal amplifier:
    Load cell normally outputs -30mV...+30mV which sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
    Example: 10kg compression load cell working with 0-10V amplifier,the load-output relationship will be 0-10kg load VS 0-10V output,it is linear within the error range.

    Load cell + Digital indicator
    Force meter can work directly with load cell without signal amplifier,here are some functions from the indicator:
    -Display force value in real time
    -Peak holding to grab the maximum force during testing
    -RS485 or RS232 interface
    -0-5V/0-10V/4-20mA analog output