10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator

10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator

    • 10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator
    • 10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator
    • 10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator
    • 10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator
  • 10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Model Number: FCMA

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 5000pcs/month
    Contact Now
    Detailed Product Description
    Material: Alloy Steel Capacity: 30kg 50kg 100kg 200kg 300kg 500kg 1000kg
    Output: Analog Output Principle: Strain Gauge Load Cell

    10kN 5kN 3kN 2kN 1kN 500N Pancake Force Sensor With Load Cell Indicator

    Universal Compression Type Force Transducer FCMA is made of high stiffness alloy steel based on foil strain gauge technology to deliver 2.0mV/V rated output proportional to the applied force. Pancake load cell FCMA offers 30kg / 50kg / 100kg / 200kg / 300kg / 500kg / 1000kg seven different measuring ranges with maximum 0.1% non-linearity of the rated output to choose from intended for both static and dynamic force measurement, low profile load cell FCMA can be used for both tension and compression measurement, low profile structure makes it also suitable for in-line force monitoring. Model FCMA is designed with a M16x1.5 threaded hole running through the center of the transducer which can be used to mount attachments such as load buttons,eye bolts or other adapters for force loading, this makes spoke type load cells very adaptable to various cases, you may find Pancake Force Sensor FCMA applicable for force measurement in injection-molding machines, press machines and material testing equipment, weight measurement for tanks, vessels and hoppers, and so on.

    Pancake Force Transducer 10kN 5kN 3kN 2kN 1kN 500N

    Dimensions

    Pancake Force Transducer 10kN 5kN 3kN 2kN 1kN 500N
    Specifications

    Capacity

    30 kg / 300N / 66lbf

    50 kg / 500N / 110 lbf

    100 kg / 1kN / 220 lb

    200 kg / 2kN / 440lb

    300 kg / 3kN / 660 lbf

    500 kg / 5kN / 1.1klb

    1000 kg / 10kN / 2.2k lbf

    Rated output 2.0mV/V
    Excitation 3-15V
    Zero balance ±0.05mV/V
    Nonlinearity ±0.1% R.O.
    Hysteresis ±0.1% R.O.
    Nonrepeatability ±0.05% R.O.
    Creep(10min) ±0.05% R.O.
    Safe overload 150% F.S.
    Ultimate overload 200% F.S.
    Compensated temperature -10...+40oC
    Operating temperature -20...+60oC
    Temperature shift zero ±0.05% R.O./10oC
    Temperature shift span ±0.05% R.O./10oC
    Input resistance 750±50 ohms
    Output resistance 700±10 ohms
    Insulation resistance >5000M ohms
    Ingress protection IP65
    Material of element Alloy steel
    Cable Ø5*2000mm 4-core shielded
    Wiring code Red--E+ Black--E- Green--S+ White--S-

     

    A load sensor is a transducer that converts a load or force acting on it into electronic signal which is proportional to the load(or force) being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply,the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the load cell.

    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: 2.0mV/V load cell with 10V power supply,the output range is 0~20mV (-20mV...+20mV for bidirectional sensor).
    Example two: 1.0mV/V load cell with 5V power supply,the output range is 0~5mV (-5mV...+5mV for bidirectional sensor).

    Load cell + Signal amplifier:
    Load cell normally outputs -30mV...+30mV which sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
    Example: 10kg compression load cell working with 0-10V amplifier,the load-output relationship will be 0-10kg load VS 0-10V output,it is linear within the error range.

    Load cell + Digital indicator
    Digital indicator can work directly with load cell without signal amplifier,here are some functions from the indicator:
    -Display force value in real time
    -Peak holding to grab the maximum force during testing
    -RS485 or RS232 interface
    -0-5V/0-10V/4-20mA analog output
    -Switch output

    10kN 5kN 3kN 2kN 1kN 500N Pancake Force Transducer With Load Cell Display

     Pancake Force Sensor With Digital Display

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)