Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSingle point load cell

Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor

Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor

    • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor
    • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor
    • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor
    • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor
    • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor
  • Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FNG

    Payment & Shipping Terms:

    Minimum Order Quantity: 10pcs
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 9920pcs/month
    Contact Now
    Detailed Product Description
    Structure: Single Point Load Cell Output: Analog
    Range: 3/6/10/15/20/30/40kg Usage: Weighing
    Type: Off-center Load Cell

    Compact Single Point Loadcell 3kg 6kg 10kg 20kg 30kg 40kg Weighing Sensor

    High Accuracy Single Point Load Cell FNG is a strain gauge based weight transducer which offers 0-3kg / 0-6kg / 0-10kg / 0-15kg / 0-20kg / 0-30kg / 0-40kg seven rated measuring ranges to choose from. Precison weighing sensor FNG delivers maximum 0.02% non-linearity of the full capacity. 1000 ohms high resistance strain gauges are used to reduce the power consumption, it is designed with 2xM6 threaded holes on each end, one end for mounting the sensor, the other end for loading. Loadcell FNG is corner trimmed for platform sizes up to 250x350mm which makes it suitable for off-center load measurement. Load Cell sensor FNG delivers stable performance within the declared working temperature range thanks to its temperature compensation process. You may find Load cell transducer FNG suitable for applications such as beehive weighing scales, force simulators, packaging machines, platform scales, feeding machines and so on.

    single point load cell 3kg 5kg 10kg 20kg 30kg

    single point loadcell 3kg 5kg 10kg 20kg 30kg

    Specifications

    Rated capacity

    3kg / 30N / 6.6lb
    6kg / 60N / 13.2lb
    10kg / 100N / 22lb

    15kg / 150N / 33lb
    20kg / 200N / 44lb

    30kg / 300N / 66lb

    40kg / 400N / 88lb

    Sensitivity 2.0 mV/V Compensated temperature -10...+40oC
    Excitation 3-15V Operating temperature -20...+60oC
    Zero balance ±0.1mV/V Temperature shift zero ±0.05% R.O./10oC
    Nonlinearity ±0.02% R.O. Temperature shift span ±0.03% R.O./10oC
    Hysteresis ±0.02% R.O. Input resistance 1130±20 ohms
    Nonrepeatability ±0.015% R.O. Output resistance 1000±10 ohms
    Creep(30min) ±0.03% R.O. Insulation resistance >2000Mohms
    Safe overload 150% F.S. Ingress protection IP65
    Ultimate overload 200% F.S. Material of element Aluminum
    Cable Ø4*400mm 4-core shielded
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-

     

    A weight sensor is a transducer that converts mechanical load into electrical signal which is proportional to the load being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV for Single Point Load Cell FNG. Overloading is the most common cause of loadcell failure, a load sensor is just like a spring in certain aspects, which will be damaged if overstretched or overloaded. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The deformation gap can be determined by loading the sensor with rated capacity, then adjust the meachnical stop to reach the bottom of the transducer. In most cases, the load cell will be used to measure load at 40-80% of the full capacity, thus the deformation gap can be adjusted using reference load a bit higher than the target load to be measured instead of the rated capacity.

    single point load cell with overload protection

    Compact Single Point Load Cell 3kg 6kg 10kg 20kg 30kg 40kg Accurate Weighing Transducer

    high accuracy weighing sensor 3kg 5kg 10kg 20kg 30kg

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)

    Other Products