Load cells,Force sensors,Torque transducers

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSingle point load cell

Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer

Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer

    • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer
    • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer
    • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer
    • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer
    • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer
  • Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer

    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FNH

    Payment & Shipping Terms:

    Minimum Order Quantity: 5pcs
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 9940pcs/month
    Contact Now
    Detailed Product Description
    Structure: Single Point Loadcell Output: Analog
    Range: 20/40/60/100/200kg Usage: Weighing
    Type: Off-center Load Cell

    Precision Single Point Load Cell 200kg 100kg 60kg 40kg 20kg Weighing Transducer

    High accuracy Single Point Load Cell FNH is a strain gauge based weight sensor which offers 0-20kg / 0-40kg / 0-60kg / 0-100kg / 0-200kg five rated measuring ranges to choose from. Single Point Load Cell FNH delivers maximum 0.02% non-linearity of the full scale. Loadcell FNH is corner trimmed for platform sizes up to 250x350mm which makes it suitable for off-center load measurement. Weight sensor FNH is able to deliver stable performance within the declared working temperature range thanks to its temperature compensation process. You may find Load Cell Transducer FNH suitable for applications such as feeding machines, force simulators, pedal force measurement and so on.

    single point load cell 200kg 100kg 50kg 20kg

    single point load cells 200kg 100kg 50kg 20kg

    Specifications

    Rated capacity

    20kg / 44 lb / 200N

    40kg / 88 lb / 400N

    60kg / 132 lb / 600N

    100kg / 220 lb / 1000N

    200kg / 440 lb / 2000N

    Sensitivity 2.0 mV/V Compensated temperature -10...+40oC
    Excitation 3-15V Operating temperature -20...+60oC
    Zero balance ±0.1mV/V Temperature shift zero ±0.05% R.O./10oC
    Nonlinearity ±0.02% R.O. Temperature shift span ±0.03% R.O./10oC
    Hysteresis ±0.02% R.O. Input resistance

    405±10 ohms

    Nonrepeatability ±0.015% R.O. Output resistance 350±5 ohms
    Creep(30min) ±0.03% R.O. Insulation resistance >2000Mohms
    Safe overload 150% F.S. Ingress protection IP65
    Ultimate overload 200% F.S. Material of element Aluminum
    Cable Ø4*1000mm 4-core shielded
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-

     

    A weight sensor is a transducer that converts mechanical load into electrical signal which is proportional to the load being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV for Single Point Load Cell FNH. Overloading is the most common cause of loadcell failure, a load sensor is just like a spring in certain aspects, which will be damaged if overstretched or overloaded. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The deformation gap can be determined by loading the sensor with rated capacity, then adjust the meachnical stop to reach the bottom of the transducer. In most cases, the load cell will be used to measure load at 40-80% of the full capacity, thus the deformation gap can be adjusted using reference load a bit higher than the target load to be measured instead of the rated capacity.

    single point load cells with overload protection

    Precision Single Point LoadCell 200kg 100kg 60kg 40kg 20kg Weight Sensor

    single point loadcell 200kg 100kg 50kg 20kg

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)

    Other Products