    Product Details:

    Place of Origin: China
    Brand Name: Forsentek
    Certification: CE
    Model Number: FH02

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Packaging Details: Shockproof carton
    Delivery Time: 3-20 working days
    Payment Terms: T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 9950pcs/month
    Contact Now
    Detailed Product Description
    Structure: Single Point Load Cell Signal: Analog
    Range: 0-20kg(Selectable) Usage: Weighing Transducer
    Type: Off Center Weight Sensor

    Small Single Point Load Cell 500g 1kg 2kg 5kg 10kg 20kg Compact Weight Sensor

    Single point load cells work by converting weight or a force that is applied against it into a analog signal. When a load is applied to a single point load cell, the resistance is changed, which leads to a change in output voltage.​High Accuracy Weight Sensor FH02 is made of aluminum alloy based on strain gauge technology. Weight transducer FH02 offers 0-500g / 0-1kg / 0-2kg / 0-3kg / 0-5kg / 0-6kg / 0-10kg / 0-15kg / 0-20kg nine rated measuring ranges to choose from. Weight Sensor FH02 is temperature compensated to deliver stable readout throughout the working temperature range. Single point load cell transducer FH02 is corner trimmed for platform sizes up to 120x120mm, suitable for off-center load measurement.Beam Type Loadcell FH02 is widely used for bench scales, weight monitoring laboratory equipment, home appliances, dosing machines and other weighing applications. Custom made service is available at Forsentek if the current specifications are not applicable.

    compact single point load cell 1kg 2kg 5kg 10kgsmall size weight sensor 1lb 2 lb 5lb 10 lb 20lb

    Specifications

    Rated capacity

    500g / 5N / 1.1 lb

    1000g / 10N / 2.2 lb

    2000g / 20N / 4.4 lb

    3000g / 30N / 6.6 lb

    5000g / 50N / 11 lb

    6kg / 60N / 13 lb

    10kg / 100N / 22 lb

    15kg / 150N / 33 lb

    20kg / 200N / 44 lb

    Sensitivity 2.0 mV/V Compensated temperature -10...+40oC
    Excitation 3-15V Operating temperature -20...+60oC
    Zero balance ±0.05mV/V Temperature shift zero ±0.03% R.O./10oC
    Nonlinearity ±0.02% R.O. Temperature shift span ±0.03% R.O./10oC
    Hysteresis ±0.02% R.O. Input resistance 410±10 ohms
    Nonrepeatability ±0.02% R.O. Output resistance 350±5 ohms
    Creep(5min) ±0.02% R.O. Insulation resistance >5000Mohms
    Safe overload 150% F.S. Ingress protection IP62
    Ultimate overload 200% F.S. Material of element Aluminum
    Cable Ø3*400mm 4-core shielded
    Wiring code

    Red--Power input+    Black--Power input-

    Green--Signal output+    White--Signal output-

     

    A Load Cell(loadcell) is a transducer that converts mechanical force into electrical signal which is proportional to the weight(or force) being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV for loadcell sensor FH02.Overloading is the most common cause of loadcell failure, a load cell is just like a spring in certain aspects, which will be damaged if overstretched. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The gap distance can be determined by loading the sensor with rated capacity,then adjust the meachnical stop to reach the bottom of the transducer.In most cases,the load cell will be used to measure load at 30-60% of the full scale,thus the gap distance can also be adjusted using reference load a little higher than the target load to be measured instead of the rated capacity.

    single point loadcell overload protection

    Small Size Single Point Load Cell 500g 1kg 2kg 5kg 10kg 20kg Compact Weight Transducer

    single point load cell 1 lb 2 lb 5lb 10 lb 20lb

    Click here to download datasheet

    Contact Details
    Force sensor torque transducer

    Contact Person: Mr. Tarik Lu

    Tel: 86-755-84536383

    Send your inquiry directly to us (0 / 3000)

    Other Products